tridium IO R module

Tridium IO R Module

Introducing an IO solution that makes the next-generation JACE controller and EDGE 10 more powerful, and your migration path straightforward.

IO R 16 and IO R 34 are part of the Niagara Framework portfolio of hardware, software and tools designed for remote monitoring and control applications that enables end-to-end automation and device-to-enterprise integration.

I/O Options: IO R 16 | IO R 34

Product Description
IOR allows the JACE 8000 to interface directly with simple non-intelligent inputs and outputs remotely located up to 4,000 feet from the JACE. The connection is established via an industry-standard RS 485 multi-drop communications bus. Multiple IO R devices can be utilized on a single JACE, providing 250+ IO points on a single JACE.
  • Ease of use: Single-tool programming inside the Niagara environment with live debugging.
  • Enhanced capability: Ability to set hold time and default states for outputs based on application needs.
  • Improved flexibility: Operates over an RS485 network and can be installed anywhere. Multiple modules can be combined so each JACE 8000 can command more than 250 points of IO.
  • Minimal wiring labor: Quick three-step process when moving from NDIO to the JACE 8000.

IO-R-16

  • 8 Universal inputs: Type 3 (10k) thermistors, 0-100K ohm, 0-10VDC,
  • 0-20 mA with external resistor
  • 4 Relay outputs (Form A contacts, 24VAC @ .5 amp rated)
  • 4 Analog outputs (0-10VDC)
  • Powered from IO-R-34
  • Connected to JACE 8000 remotely over a shielded RS485 bus

IO -R-34

  • 16 Universal inputs: Type 3 (10k) thermistors, 0-100K ohm
  • 0-10VDC, 0-20 mA with external resistor
  • 10 Relay outputs (Form A contacts, 24VAC @ .5 amp rated)
  • 8 Analog outputs (0-10VDC)
  • Powered from a 24VAC/DC source
  • Can power up to 4 IO-R-16 modules
  • Connected to JACE 8000 remotely over a shielded RS485 bus
You might also like
Tridium JACE 8000 IoT Controller

IoT/BMS Controller running Niagara 4

View
Tridium Niagara 4 Driver solutions

Wide range of flexible drivers for your system

View
Tridium Niagara EDGE 10 Controller

IP-based Niagara controller w/ 10 built-in IO

View
Tridium IO-R 34 JACE Expansion

16xUI, 10xRO, 8xAO for JACE or EDGE

View

Get pricing and enquiries


Enhance your Niagara station

Exclusive Niagara drivers that overcome integration challenges and enhance productivity delivering projects