Switch Energy Meter

4-noks

The wall-mounted ZR-SWITCH-M device is part of the ZB-Connection range. It includes a meter for electric energy and a relay to switch on and switch off loads up to 2,5 kW.

GET A QUOTE

The ZR-SWITCH-M device is mounted to the wall and is connected to an equipment directly or through a socket or a splitter. Once attached to a wireless ZigBee ZB-Connection network you can remotely switch on and switch off the device and always remotely measure the instant active power and the energy spent. Moreover is available stand-by killer and override button functions. You can set a power limit under which the device is meant to be in stand-by killer mode and so can be automatically turned off. With the override button the user can override the last command from the Gateway. Such tasks are carried out after simple Modbus commands sent to ZB-Connection network that transform them in wireless commands.

The device is continuously supplied by a 230 Vca output, so it can also work as a repeater or a “father” device for battery supplied sensors.

  • Real Time Electricity Active Power Measurement up to 2,5 kW
  • Electricity Energy Counter
  • Remote switch up to 2,5kW
  • Stand-by killer
  • Override push-button
  • ModBus profile on ZigBee platform
  • Router function

General characteristics

  • Chip Ember EM250
  • Compatible IEEE 802.15.4
  • Stack EmberZnet 3.5.x (ZigBee PRO)
  • Modbus/RTU
  • Address settable through commands launched by radio

RF characteristics

  • Frequency: 2405 MHz ÷ 2480 MHz
  • Modulation: DSSS
  • Nominal transmission power: 2mW (3 dBm)
  • Receiver sensitive: -95 dBm
  • Internal antenna gain: 0 dB
  • Outdoor/indoor range: 100m/30m

Supply

  • 90/250 Vca ; 1W; 50/60Hz

Measurement

  • Active Power [W] Active Energy [Wh] Energy consumption measurement time [second]

Relay

  • 250V Contacts
  • Max. load:
  • -Resistive: 10A
  • -Incandescene lamp: 10A
  • -Fluo lamps /transformers: 4A
  • Duration: 100.000 cycles with resistive load

Connection

  • End morsels (5,08 mm pitch)

Environment Parameters

  • Operating temperature: 0 ÷ +50°C; <80% U.R. non condensing
  • Storage temperature: -20 ÷ +70°C; <80% U.R. non condensing

Compliant with 2006/95/EEC, 89/336/EEC, 99/5/EEC directives, Product law applied

  • ETSI EN 300 328: Radio Compatibility for digital wide band transmissions
  • ETSI EN 301 489: Radio Compatibility
  • EN 55014-1:2006 + A 1:2009: Electromagnetic Compatibility – Immunity
  • EN 61000-3-2:2006: Electromagnetic Compatibility – Emissions
  • EN 61000-3-3:2008: Electromagnetic Compatibility – Emissions
  • EN 55014-2: Electromagnetic Compatibility – Immunity